Logo

Log In Sign Up |  An official publication of: American College of Emergency Physicians
Navigation
  • Home
  • Multimedia
    • Podcasts
    • Videos
  • Clinical
    • Airway Managment
    • Case Reports
    • Critical Care
    • Guidelines
    • Imaging & Ultrasound
    • Pain & Palliative Care
    • Pediatrics
    • Resuscitation
    • Trauma & Injury
  • Resource Centers
    • mTBI Resource Center
  • Career
    • Practice Management
      • Benchmarking
      • Reimbursement & Coding
      • Care Team
      • Legal
      • Operations
      • Quality & Safety
    • Awards
    • Certification
    • Compensation
    • Early Career
    • Education
    • Leadership
    • Profiles
    • Retirement
    • Work-Life Balance
  • Columns
    • ACEP4U
    • Airway
    • Benchmarking
    • Brief19
    • By the Numbers
    • Coding Wizard
    • EM Cases
    • End of the Rainbow
    • Equity Equation
    • FACEPs in the Crowd
    • Forensic Facts
    • From the College
    • Images in EM
    • Kids Korner
    • Medicolegal Mind
    • Opinion
      • Break Room
      • New Spin
      • Pro-Con
    • Pearls From EM Literature
    • Policy Rx
    • Practice Changers
    • Problem Solvers
    • Residency Spotlight
    • Resident Voice
    • Skeptics’ Guide to Emergency Medicine
    • Sound Advice
    • Special OPs
    • Toxicology Q&A
    • WorldTravelERs
  • Resources
    • ACEP.org
    • ACEP Knowledge Quiz
    • Issue Archives
    • CME Now
    • Annual Scientific Assembly
      • ACEP14
      • ACEP15
      • ACEP16
      • ACEP17
      • ACEP18
      • ACEP19
    • Annals of Emergency Medicine
    • JACEP Open
    • Emergency Medicine Foundation
  • About
    • Our Mission
    • Medical Editor in Chief
    • Editorial Advisory Board
    • Awards
    • Authors
    • Article Submission
    • Contact Us
    • Advertise
    • Subscribe
    • Privacy Policy
    • Copyright Information

Using Point-of-Care Ultrasound to Confirm Endotracheal Tube Placement

By Ken Milne, MD | on May 17, 2019 | 0 Comment
Skeptics' Guide to EM
  • Tweet
  • Click to email a link to a friend (Opens in new window) Email
Print-Friendly Version
Using Point-of-Care Ultrasound to Confirm Endotracheal Tube Placement

The Case

A 52-year-old patient is in cardiac arrest and needs endotracheal intubation. You’ve read some studies recently saying point-of-care ultrasound (POCUS) could confirm placement.

You Might Also Like
  • Confirmation and Assessment of Endotracheal Tube Location
  • Making NG Tube Placement Less Horrendous
  • Videolaryngoscope Helps Residents Learn Neonatal Endotracheal Intubation
Explore This Issue
ACEP Now: Vol 38 – No 05 – May 2019

Background

There are a number of ways to confirm endotracheal tube (ETT) placement. Quantitative waveform capnography is thought to be one of the best methods. However, in cardiac arrest, some studies suggest it is correct only about two-thirds of the time.1–3 

An ACEP policy statement lists various methods to confirm ETT placement, which include:

  • A physical exam (ie, auscultation of chest and epigastrium, chest wall movement, and condensation/fogging in the tube)
  • Direct visualization or video laryngoscope of the tube passing through the vocal cords
  • Pulse oximetry
  • Chest X-ray
  • Esophageal detector devices
  • End-tidal carbon dioxide (CO2) detection (ie, continuous waveform capnography, colorimetric capnography, and non-waveform capnography)

Clinical Question

What is the accuracy of POCUS for ETT placement confirmation?

Reference

Gottlieb M, Holladay D, Peksa GD. Ultrasonography for the confirmation of endotracheal tube intubation: a systematic review and meta-analysis. Ann Emerg Med. 2018;72(6):627-636.

  • Population: Prospective or randomized controlled trial (RCT) of adults undergoing assessment of transtracheal POCUS for ETT placement confirmation
    • Excluded: Case reports, case series, retrospective studies, cadaver studies, pediatric studies, and conference abstracts
  • Intervention: Transtracheal POCUS to confirm ETT placement
  • Comparison: Confirmatory testing of ETT placement such as end-tidal capnography, colorimetric capnography, or direct visualization
  • Outcome:
    • Primary Outcome: Accuracy of transtracheal POCUS versus other forms of confirmation
    • Secondary Outcome: Time to confirmation and subgroup analyses

Authors’ Conclusions

“Transtracheal sonography is rapid to perform, with an acceptable degree of sensitivity and specificity for the confirmation of endotracheal intubation. Ultrasonography is a valuable adjunct and should be considered when quantitative capnography is unavailable or unreliable.”

Table 1: Diagnostic Accuracy of Transtracheal POCUS  for ETT Placement

(click for larger image) (Table 1: Diagnostic Accuracy of Transtracheal POCUS for ETT Placement

Key Results

The search identified 15 prospective observational studies and two RCT, including a total of 1,595 patients. A majority of the studies (12 out of 17) were performed in the emergency department. The mean patient age was 55 years, with 57 percent being male. The esophageal intubation rate was 15 percent.

  • Primary Outcome: Diagnostic accuracy of transtracheal POCUS for ETT placement (see Table 1)
  • Secondary Outcome: Mean time to confirmation was 13.0 seconds (95% CI, 12.0–14.0).
  • Subgroup Analyses: These did not demonstrate a significant difference by location, provider specialty, provider experience, transducer type, or technique.

Evidence-Based Medicine Commentary

  1. Included Studies: The 17 studies included were relatively small with wide confidence intervals. Fifteen of the 17 were observational studies. Only 216 patients (14 percent) were in RCTs. Thirteen of the 17 studies used convenience sampling instead of consecutive patients, which can introduce bias and thereby limit the strength of the conclusions.
  2. Lack of Gold Standard: A number of methods are available and often used in combination, but there is no gold standard. Each confirmation method has limitations. Auscultation can prove inaccurate, especially in loud environments. Chest X-ray takes too long, and as previously mentioned, capnography in cardiac arrest has low sensitivity.
  3. Esophageal Intubation Rate: This was very high (15 percent) and may be due to studies including medical students and residents in addition to attending physicians. A previous study has shown the rate of esophageal intubation in the emergency department to be only 3 percent.4
  4. Fast: POCUS for ETT placement was not only accurate but also fast, with a mean of 13 seconds. For comparison, it takes 48 seconds for the standard auscultation and capnography combination.5 It is not known if this difference in time results in a patient-oriented benefit.
  5. Publication Bias: The funnel plot analysis demonstrated evidence of publication bias. This is a well-known phenomenon in the medical literature and could have skewed the results to make transtracheal POCUS ETT confirmation look better than it actually is.

Bottom Line

In conjunction with other methods, POCUS represents a potentially fast and accurate method to help confirm ETT placement.

Pages: 1 2 | Single Page

Topics: Endotracheal IntubationPOCUSPoint-of-Care Ultrasound

Related

  • Case Report: Rapid Diagnosis of Acute Aortic Dissection with POCUS

    June 11, 2025 - 0 Comment
  • Airway Considerations in Prehospital Cardiac Arrest

    May 9, 2025 - 0 Comment
  • The SPEED Protocol: Using Ultrasound To Detect Acute Aortic Dissection

    May 10, 2024 - 0 Comment

Current Issue

ACEP Now: June 2025 (Digital)

Read More

About the Author

Ken Milne, MD

Ken Milne, MD, is chief of emergency medicine and chief of staff at South Huron Hospital, Ontario, Canada. He is on the Best Evidence in Emergency Medicine faculty and is creator of the knowledge translation project the Skeptics Guide to Emergency Medicine.

View this author's posts »

No Responses to “Using Point-of-Care Ultrasound to Confirm Endotracheal Tube Placement”

Leave a Reply Cancel Reply

Your email address will not be published. Required fields are marked *


*
*

Wiley
  • Home
  • About Us
  • Contact Us
  • Privacy
  • Terms of Use
  • Advertise
  • Cookie Preferences
Copyright © 2025 by John Wiley & Sons, Inc. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies. ISSN 2333-2603